Simpson Strong-Tie Wood Construction Connectors
Simpson Strong-Tie ® Wood Construction Connectors DGF/DGBF/DGHF Fire Wall Hangers (cont.)
Allowable Loads on 2x4 or 2x6 Wall
DF/SP
SPF/HF
Fasteners (in.)
Download (100/125)
Download (100/125)
Joist Depth (in.)
Web Stiff Req’d
Code Ref.
Model
Ga.
Uplift (160)
Uplift (160)
(2) 2x, 4x Nailer
(2) 2x, 4x Nailer
Top
Face
Joist
Studwall 2x, 3x Nailer
Studwall 2x, 3x Nailer
(6) 0.148 x 3 (4) 0.148 x 3 (2) 0.148 x 1 1/2
— 130 1,160 — 1,160 110 1,130 — 1,130
220 1,350 1,350 1,350 190 1,315 1,315 1,315
12 7 1/4 to 11 1/4
— (6) 0.148 x 1 1/2
(6) 0.148 x 1 1/2
DGF
ü
(6) 0.148 x 3
— (6) 0.148 x 1 1/2
315 1,420 — 1,420 270 1,385 — 1,385
ü
(6) 0.148 x 3 (4) 0.148 x 3 (2) 0.148 x 1 1/2
— 130 1,160 — 1,160 110 1,130 — 1,130
IBC, FL, LA
DGF
12 11 7/8 to 24
315 1,620 1,620 1,620 270 1,450 1,450 1,450
(6) 0.148 x 1 1/2
— (6) 0.148 x 1 1/2
ü
(6) 0.148 x 3
— (6) 0.148 x 1 1/2
315 1,705 — 1,705 270 1,525 — 1,525
ü
855 2,030 2,030 2,030 650 1,855 1,855 1,855
(5) 0.148 x 1 1/2 (2) 0.148 x 3 (8) 0.148 x 1 1/2
ü
DGHF
10 7 1/4 to 24
(5) 0.148 x 3 (2) 0.148 x 3 (8) 0.148 x 1 1/2
900 2,135 — 2,135 770 1,950 — 1,950
ü
DGBF (over studs) 7 9 1/2 to 24 (8) 0.148 x 3 (4) 0.148 x 3 (8) 0.148 x 3 ü
1,040 3,015 — 3,015 890 2,280 — 2,280
315 1,620 — 1,620 270 1,350 — 1,350 — 870 2,010 — 2,010 755 1,705 1,550 —
DGHF (skewed)
10 7 1/4 to 24 (5) 0.148 x 3 (2) 0.148 x 3 (8) 0.148 x 1 1/2
ü
DGHF (offset)
10 7 1/4 to 24 (5) 0.148 x 3 (2) 0.148 x 3 (8) 0.148 x 1 1/2
ü
1. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other loads govern. 2. Allowable loads are for 2x4 minimum stud wall or nailer. Back-to-back installations require a minimum 2x6. Wall design by designer. 3. For hangers spaced closer than 16" o.c., the allowable load shall be reduced proportionately. 4. DGBF installation requires a minimum (2) 2x4 stud or post in the wall at hanger location. Post design by designer. 5. DGHF hangers may be skewed up to 45. Skew and offset options cannot be combined. 6. Face nails for DGHF (offset) may be installed in any two holes. 7. DGF and DGHF may be installed over 5/8 " maximum wood structural panel sheathing. For DGF, use 0.87 of the table loads for uplift and download. For DGHF, use 0.91 of table loads for uplift and full table downloads. Sheathing shall be installed flush with top of the wall and fastened per code. 8. Fasteners: Nail dimensions are listed diameter by length. See pp. 21–22 for fastener information.
Fire Wall Hangers
Face of wall
1 ⁄ " drywall gap
End of joist stop End of truss
DGF — 1 ¾ " DGHF — 1 ⁄ " DGBF — 1 ¾ " truss gap
⅛ " max.
DGHF Hanger (DGF similar) Top View with Gap
DGF Hanger on Stud Wall with Trusses
DGF hanger width plus 1/4"
C-C-2021 ©2021 SIMPSON STRONG-TIE COMPANY INC.
2¾ "
DGHF and DGBF hanger width plus 1/4"
3"
Drywall Notches
DGBF Hanger Installed with Double Studs
236