Stock Synthetic Felt Comparison Guide

Stock Synthetic Felt Comparison Guide

Stock Synthetic Felt Guide

We Make Roo ng Safer

Ce r t a i n Te e d

High Performance Synthetic Roofing Underlayment

CertainTeed’s DiamondDeck™ High Performance Synthetic Underlayment

is manufactured to provide best-in-class performance in terms of both weather protection and contractor safety.

DiamondDeck is a synthetic, scrim-reinforced, water-resistant underlayment that can be used beneath shingle, shake, metal or slate roofing. It has exceptional dimensional stability compared to standard felt underlayment. Felt underlayment can wrinkle when it becomes wet and “telegraph” those wrinkles through to the shingles applied over it. DiamondDeck eliminates this problem and its special top surface treatment provides excellent slip resistance, even when wet. DiamondDeck’s 10 square roll (4-foot wide and 250-foot long) is easier to handle and faster to apply than standard felt rolls.

Features/Benefits Lightweight – Easy to work with and carry

Excellent 6-month UV stability – Finish roof when you are ready Excellent tear resistance – Durability, reduced puncture risk Superior wet/dry traction – Work faster and safer Cool gray surface color – More comfortable working environment

Product Specifications Construction: 12 mil multi-layer Roll size: 10 squares (48" wide x 250' long) Weight per roll: 38 lbs. Rolls per pallet: 25 Pallet weight: 1,040 lbs.

ASK ABOUT OUR OTHER CERTAINTEED PRODUCTS AND SYSTEMS: EXTERIOR: ROOFING • SIDING • WINDOWS • FENCE • RAILING • TRIM • DECKING • FOUNDATIONS • PIPE INTERIOR: INSULATION • GYPSUM • CEILINGS

CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482

Professional: 800-233-8990 Consumer: 800-782-8777 www.certainteed.com

Code No. 20-30-370 © 2/10 CertainTeed Corporation, Printed in U.S.A.

RoofRunner™ lightweight synthetic polymer-based underlayment outperforms felt and outclasses other synthetics. Designed for use on roof decks as a water-resistant layer beneath asphalt roofing shingles, this scrim-reinforced underlayment includes a special top surface treatment that provides excellent slip resistance, even when wet. Large roll size - 4 ft wide x 250 ft long - speeds application. ROOFRUNNER ™ L i g h t we i g h t S y n t h e t i c Un d e r l a yme n t

SPECIFICATIONS • Dimensions: 48" wide x 250' • Roll Size: 1,000 sq. ft. • Coverage: 937.5 sq. ft. • Weight: 23 lbs. • UV Exposure: 90-day (based on standard accelerated QUV testing) • Warranty: See Limited Warranty for Details • Rolls per Pallet: 49

STANDARDS AND CODES RoofRunner conforms to: • Physical requirements of

both ASTM D226 and D4869 • UL 790 / ASTM E108 Class A Fire Resistance with Class A Roof Shingle • ICC-ES AC188 • Florida Approval FL 21841

CertainTeed Corporation ROOFING • SIDING • TRIM • DECKING • RAILING • FENCE • GYPSUM • CEILINGS • INSULATION 20 Moores Road Malvern, PA 19355 Professional: 800-233-8990 Consumer: 800-782-8777 certainteed.com

©3/17 CertainTeed Corporation. Printed in the USA. Code No. 20-20-3695

!"#$%&"'(")*$

>?6< @A' B,22,85 CD01<6C'89 05;6<214=653 C82;

()'!"#$%&'*'+,-.'/012,34'!453.63,7'&889,5-':5;6<214=653

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

G +9:;<=<>?@+0'*$"*$#+.&10+++++++ + %$.1.*'"*+8'&A1"5+.!%-'7$ G +H'*$%+%$.1.*'"*+E+IJ+)1&+*417A"$.. G +K0+*,+LM+#'(.+KN+$F0,.!%$+%'*1"53 G +IJ+*1)$.+.*%,"5$%+*4'"+OPM+-$&* PM+($'%.+&1)1*$#+8'%%'"*( G +IMMR+%$7(7&'2&$3+1"$%*+*,+),&#+'"#+ '"#+)1&#$83+8'*$%+%$.1.*'"* 0,&(,&$-1"+7,".*%!7*1," G +Q&&+*$)0$%'*!%$+0$%-,%)'"7$+ G +S!.*,)+&,5,+0%1"*1"5+'6'1&'2&$ ETMUV+*,+JTMUV

!"#$%&%'"(%)*+,,*-%./012,3%45%678%9:7-%5/0/;/

We Make Roo ng Safer

%

$

$

&

#

'

"

(

!

!"#$%&"'(")*$

!"##$%&'()*&'+%,'&%-.///%0(%1''2 -//3%&'454#67#' 862'&*6#%4"9,"$*2*": ;<%&'$*$26:4' =&'6>*:?%$2&':?2@%A0B8%C%D/EF%8C%G%HC B'6&%$2&':?2@%A0B8%CFDEE%8C%G%HC I62'&%$@"J'&%'K,"$)&'%A0B8%C%FLMN O'&9'67*#*25%A0B8%PNM 8)##':%=)&$2 Q"9*:6#%2@*4>:'$$%A0B8%C-RRR B'9,'&62)&'%&6:?' P:@6:4'+%$#*,%&'$*$26:2%$)&164' S*9*2'+%J6&&6:25 !"#$%&"'(")*$#$)+,(- $./0121034156#7#$4368398 S':?2@%G%J*+2@%,'&%&"## I'*?@2%G%$(T%12T%,'&%&"## !"##$%,'&%,6##'2%]FF^%K%FF^_ !"##$%,'&%2&)4>#"6+%W%EM%,6##'2$

)

2

*

1

$)+,(- FL^%K%`D/12 ``%#7$%]-/%>?_%G%-///%$(T%12T FN -RMF - a'$ O"#5"#'1*: N/%+65$ -/R%#7$%]FN%>?_%G%NM%#7$%]FF%>?_ `D%#7$%]--%>?_%G%`E%#7$%]-/%>?_ O6$$ b/T/D%O'&9$

:;<#!/=4 EM^%K%R`12 FD#7$G%`-M%$(T12T `D -///

+

*

,

0

#

-

"

/

!

.

%

!

"#

D Q" A$,@6#2 Q":'

!"#$

!"#$$%# #$&'%()*+

" % * & '

! ( )

QA QA QA -TRD%O'&9$ QA M/%9*#$

$

# $ % % $

(

!

--E%,$* -`%9*#$ WF/c%X%2"%`F/c%X PK4'##':2%]Z!YO0O[B_ E/%5'6&$

GHE%I"&$!I$D9$

>958?04#@//4A#59#/B0//8A#3==#9/C?19/8#D?1=816E#058/AF# G$"H#IJJK#"L./A#)#7#))M#G$"H#INOKPM#*G&Q*$G#GRJ;S;M# *G&Q*$G# GJJ

=6$*4 Q":'

B@'%+626%$@"J:%67"U'%*$%76$'+%":%2@'%2'$2%6U'&6?'$%6:+%*:+',':+':2%2'$2%&',"&2$T%B@'&'%46:%7'%6%VGW-/3%U6&*62*":%*:%2@'% *:+*U*+)6#%2'$2%&'$)#2$T%B@*$%&',"&2%$@")#+%:"2%7'%4":$*+'&'+%6$%6%J6&&6:25%1"&%2@'%96:)1642)&'&T%B@'%96:)1642)&'&%*$%:"2%&'$,":$*7#'% 1"&% 2@'% 9*$&',&'$':262*":% "&% 9*$*:2'&,&'262*":% "1% 2@'% +626% 75% 2@'% &'6+'&T% O#'6$'% 1*:+% ")2% 9"&'% 67")2% 2@'% ,&"+)42% 75% 46##*:?% -WLFFWEDEWNLEN%"&%U*$*2%JJJT12$5:T4"9T%B@'%XB%0YS$%"1%XB%05:2@'2*4$%Y:4T

Rev: April 15, 2020

<'$'$%=>%)30*?,*@AB%C0AD%E22%+@1?*B%+,B,+F,;D

We Make Roo ng Safer

Over 35 Million squares of underlayment sold

FT SYNTHETICS

FT PLATINUM – Premium Grade Synthetic Roofing Underlayment

PLATINUM is an industry leading, premium quality, mechanically attached synthetic roofing underlayment designed for steep slope roofing to provide a lasting secondary layer of protection against wind driven rain, shingle blow offs, and damage caused by adverse weather conditions.

• GRIPSPOT™ patented slip resistant walking surface • Superior water holdout (Passes Modified ASTM D1970) - 20 mil thickness • Up to 6 months UV exposure rating, LIFETIME limited warranty • 20 times stronger than #30 felt • 100% recyclable, inert to mold and mildew, water resistant polyolefin construction • Custom logo printing available • All temperature performance -40°F to 240°F

PLATINUM underlayment offers; extreme durability, higher value for your dollar, and unmatched safety and reduced liability for your crew with its superior traction patented GRIPSPOT™ walking surface. GRIPSPOT™ technology with its raised fibrous traction spots and smooth channels for shedding water provides faster dry times and unmatched slip resistance in all types of weather and surface conditions; dry, wet, frozen, and dusty. PLATINUM underlayment is light weight, easy to carry, cool to the touch, and remains pliable in all weather conditions. It will not shrink in the heat, lays flat, and stays in place due to a high quality non-slip backside coating. PLATINUM underlayment is designed for residential or commercial use under; metal, tile, slate, cement, shake or shingle primary roofing materials. It also meets and exceeds all required industry standards.

5690 - 268 Street, Langley BC V4W 3X4, Canada

We Make Roo ng Safer

S

P

P

O

I

T

R

G

FT SYNTHETICS

FT SYNTHETICS PLATINUM Specification & Standard

W

E

A

PLATINUM 48” x 250ft 35 lbs (16 kg) / 1000 sq. ft. 36 1152 1 Yes 164 lbs (74 kg) / 152 lbs (69 kg) 40 lbs (18 kg) / 37 lbs (17 kg) Pass <0.05 Perms Polyolefin 180 days

#30 Felt 36” x 72ft 45lbs/ 216 sq.ft. 25 1000

C

L

A

K

F

I

Length / width per roll Weight / sq. ft. per roll Rolls per pallet (48” x 48”) Rolls per truckload - 32 pallets

N

R

U

G

S

6

UV

Rolls required per 1,000 Sq feet 100% recyclable Material composition UV resistance Breaking strength ASTM D 5034 MD / CD Tear strength ASTM D4533 MD / CD Water shower exposure ASTM D 4869 Permeability ASTM E96 Mullen Burst Nominal thickness ASTM D1777 Temperature range Enhanced slip resistant surface Limited warranty

5 No Asphalt None

MTHS

CLASS A ASTME108

T I

F E L I

M D

L I

E

NA NA NA 1.75 Perms NA 60 mils

N T T E

M I

⭐⭐

⭐⭐

W A R R A

Y

130 psi 20 mils -40° F to 240° F Excellent (GRIPSPOT) Lifetime

®

NOA 16-0510.30 Product meets or exceeds all required building codes: ASTM D226 Types I & II, ASTM D4869, CAN/CSA A123.3, CAN/CSA A220.1, Florida Building Code # FL20853, California Building Code Compliant, Class A Fire ASTM E108, CCRR 1028, AC188, Texas Department of Insurance. Miami-Dade NOA 16-1510.30, RCABC Roofstar

Basic None

The data shown above is based on the test averages and independent test reports. There can be a +/-10% variation in the individual test results. This report should not be considered as a warranty for the manufacturer. The manufacturer is not responsible for the misrepresentation or misinterpretation of the data by the reader. Please find out more about the product by calling 1-844-353-9839 or visit www.ftsyn.com. The PLATINUM and GRIPSPOT™ logos are registered trademarks of FT Synthetics Inc.

Rev: April 15, 2020

©2020 FT Synthetics Inc. All rights reserved.

We Make Roo ng Safer

WE HAVE YOU COVERED SYNTHETIC ROOF UNDERLAYMENT

REX™ TECHNOply™

HOUSEWRAP HOUSEWRAP SEAMING TAPE TEMPORARY ROOF PROTECTION

TECHNOply™ is a 100% synthetic woven roof underlayment offering high tear strengths, a proprietary walking surface and most important a green solution to today’s ecological building technology. TECHNOply™ is the GREEN answer to asphaltic felt paper. • Manufactured from post industrial recycled materials • 25 times stronger than asphaltic felt papers • UV resistant and can be left exposed for up to 6 months • 25 Year warranty - guaranteed to shed water • Pre-printed nailing pattern and overlap lines speeds installation

REX™ TECHNOply™

ROLL SIZE (ROLLS PER PALLET)

PRODUCT SPECIFICATIONS

TEST METHOD

Roll Width

48 in.

48 in. x 250 ft. (48)

48 in. x 125 ft. (60)

Weight Per Square

2.0 lbs. 25 Years

Warranty

Water Transmission

Pass

ASTM D-4869 ASTM D-5034

Tensile Strength

MD

217 lbs. 198 lbs. 36 lbs. 36 lbs.

CD

Tear Strength

MD

ASTM D-4533

CD

Pliability

Pass Pass

ASTM D-226 ASTM D-7349

Nail Sealability

CODE LISTINGS International Code Council ICC ESR-1601 Miami/Dade Building Code NOA 15-0428.14 Florida Building Code FL# 12512

Alpha ProTech Engineered Products, Inc. 301 South Blanchard St. Valdosta, GA 31601 866-312-1837

Manufacturing & Distribution Facilities Valdosta, Georgia Nogales, Arizona Salt Lake City, Utah

WE HAVE YOU COVERED SYNTHETIC ROOF UNDERLAYMENT

REX™ TECHNOply™

HOUSEWRAP HOUSEWRAP SEAMING TAPE TEMPORARY ROOF PROTECTION

REX™ TECHNOply™ INSTALLATION 1. Please insure the roof deck is clean, smooth, and dry prior to beginning installation. 2. TECHNOply™ is laid out horizontally (parallel) to the eave with the printed side up, with 3” (76mm) horizontal laps and 6” (152 mm) vertical laps. On roof slopes less than 4:12, TECHNOply™ should be lapped at 24” (61 cm) or to center line as printed, over the underlying course. 3. TECHNOply™ should be attached to the roof using plastic cap roofing nails or staples having a 1” (25mm) diameter plastic cap. Spacing should be at 6” (15 cm) on center at both horizontal and vertical caps for normal wind zones or high wind zones and coastal areas. In all cases fasten at 12” (30 cm) from end laps of the roll in the field of the roof. The pre-printed nail pattern spacing described above applies to normal as well as high wind conditions. 4. The use of staples, 3/8” head diameter EG smooth shank roofing nails or 12 gauge corrosion resistant ring shank nail having a 1” diameter cap or ting tag to attach TECHNOply™ is permitted only when the final roof covering is to be installed within twenty-four hours. Pneumatic staple guns are not recommended. 5. Where seams and joints require the use of sealant or adhesives, use a high quality, low solvent, asbestos free, plastic roofing cement meeting ASTM D-4586 Type 1, Federal Spec SS-153 Type 1 and consult manufacturer’s installation instructions. 6. Depending on roof pitch and surface conditions, it is recommended that roof jacks, toe-boards or a storage platform be secured to support roofing materials placed on roof. 7. TECHNOply™ is not designed for indefinite outdoor exposure, and it is recommended that installation of the final roof covering take place within 6 months. 8. As with any roofing product, always be careful to observe safe roofing codes and practices as by OSHA Standard – 29 CFR Fall Protection Systems Criteria and Practices – 1926.502.

Alpha ProTech Engineered Products, Inc. 301 South Blanchard St. Valdosta, GA 31601 866-312-1837

Manufacturing & Distribution Facilities Valdosta, Georgia Nogales, Arizona Salt Lake City, Utah

LIT EPB 024 05/2016

WE HAVE YOU COVERED SYNTHETIC ROOF UNDERLAYMENT

REX™ SynFel t

HOUSEWRAP HOUSEWRAP SEAMING TAPE TEMPORARY ROOF PROTECTION

REX™ SynFelt is a high strength woven synthetic roof underlayment that can save you 50% in labor and time expense, compared to 30# felt. • Slip resistant walking surface AND back surface – additional grip with two sided slip resistance • 20 times stronger than asphaltic felt – won’t tear off, buckle or curl when wet • UV resistant and can be left exposed for up to 6 months • Limited lifetime warranty – exceeds the needs of any final roof covering • Pre-printed nailing pattern and overlap lines speeds installation

REX™ SynFelt PRODUCT SPECIFICATIONS

ROLL SIZE (ROLLS PER PALLET)

TEST METHOD

Roll Width

48 in.

48 in. x 250 ft. (35)

48 in. x 125 ft. (54)

Weight Per Square

2.8 lbs. Lifetime

Warranty

Water Transmission

Pass

ASTM D-4869 ASTM D-5034

Tensile Strength

MD

96 lbs. 116 lbs. 30 lbs. 28 lbs.

CD

Breaking Strength

MD

ASTM D-5034

CD

Pliability

Pass Pass

ASTM D-226 ASTM D-779

Water Ponding

CODE LISTINGS International Code Council ICC ESR-1601 Miami/Dade Building Code NOA 15-0428.14 Florida Building Code FL# 12512

Alpha ProTech Engineered Products, Inc. 301 South Blanchard St. Valdosta, GA 31601 866-312-1837

Manufacturing & Distribution Facilities Valdosta, Georgia Nogales, Arizona Salt Lake City, Utah

WE HAVE YOU COVERED SYNTHETIC ROOF UNDERLAYMENT

REX™ SynFel t

HOUSEWRAP HOUSEWRAP SEAMING TAPE TEMPORARY ROOF PROTECTION

REX™ SYNFELT INSTALLATION 1. Please ensure the roof deck is clean, smooth, and dry prior to beginning installation. 2. REX™ SynFelt is laid out horizontally (parallel) to the eave with the printed side up, with 3” (76 mm) horizontal laps and 6” (152 mm) vertical laps. On roof slopes less than 4:12, REX™ Syn-Felt should be lapped at 24” (61 cm) or to center line as printed, over the underlying course. 3. REX™ SynFelt should be attached to the roof using plastic cap roofing nails or staples having a 1” (25 mm) diameter plastic cap, 3/8” diameter EG smooth shank roofing nails, 12 gauge corrosion resistant ring shank fastener having a 1” diameter corrosion resistant round cap or tin tag. Spacing should be at 8” (20 cm) on center at both horizontal and vertical caps for normal wind zones. In high wind zones and coastal areas, REX™ SynFelt should be fastened at 4” (101 mm) at both horizontal and vertical laps. In all cases fasten at 24” (61 cm) on center along the center of the roll in the field of the roof. The pre-printed nail pattern spacing described above applies to normal as well as high wind conditions. 4. The use of staples to attach REX™ SynFelt is permitted only when the final roof covering is to be installed immediately afterward. Pneumatic staple guns are not recommended. 5. Where seams and joints require the use of sealant or adhesives, use a high quality, low solvent, asbestos free, plastic roofing cement meeting ASTM D-4586 Type 1, Federal Spec SS-153 Type 1 and consult manufacturer’s installation instructions. 6. Depending on roof pitch and surface conditions, it is recommended that roof jacks, toe-boards or a storage platform be secured to support roofing materials placed on roof. 7. REX™ SynFelt is not designed for indefinite outdoor exposure, and it is recommended that installation of the final roof covering take place within 6 months. 8. As with any roofing product, always be careful to observe safe roofing codes and practices as by OSHA Standard – 29 CFR Fall Protection Systems Criteria and Practices – 1926.502.

Alpha ProTech Engineered Products, Inc. 301 South Blanchard St. Valdosta, GA 31601 866-312-1837

Manufacturing & Distribution Facilities Valdosta, Georgia Nogales, Arizona Salt Lake City, Utah

LIT EPB 005 05/2016

INSTALLATION INSTRUCTIONS Titanium ® UDL25 is an air, water and vapor barrier (.06 perms) and therefore should be installed above a properly ventilated space(s). It is recommended to follow all building codes applicable to your geographical region and structure type. DECK PREP: All protrusions from the deck area must be removed and ensure the deck has no voids, damaged or unsupported areas. Deck surface should be free of debris, dry and moisture free. USE: UDL25 must be covered by primary roofing within 180 days of application. UDL25 is designed for use under all primary roofing types including; Metal, Shake and Shingle roofing. APPLICATION: For slopes 4:12 and higher UDL25 is to be laid out horizontally (parallel) to the eave with the printed side up. Horizontal laps should be 4" and vertical laps should be 6"and anchored approximately 1" in from the edge. For low slope applications (less than 4:12) it is recommended to overlap 50% plus 1", for complete definition of low slope and guidelines consult authorities having jurisdiction. UDL25 product is not recommended for slopes less than 2:12. The use of a roofing hammer, hatchet hammer, pneumatic air or gas driven fastener tools is acceptable. The use of a straight edge cutting knife is recommended. FASTENERS: For same day coverage with primary roofing UDL25 can be anchored with corrosive resistant 3/8" head x 1" leg roofing nails (ring shank preferred, smooth leg acceptable). The use of every other anchoring location printed on the product is also acceptable. DO NOT USE STAPLES: The use of staples to penetrate UDL25 will void warranty. ANCHORING: All anchoring nails must be flush, 90 degrees to the roof deck, and tight with the underlayment surface and the structural roof deck. Where seams and joints require sealant or adhesive use a low solvent plastic roofing cement meeting ASTM D-4586 Type 1, or Federal Spec SS-153 Type 1 such as Karnak, Henry, DAP, MB, Geocel or equivalent. Acceptable alternatives are butyl rubber, urethane, and EDPM based caulk or tape sealant. EXTENDED EXPOSURE: If Titanium UDL25 product will be exposed longer than 1 day but less than 5 days then it is recommended to anchor using corrosive resistant 3/8" head x 1" leg roofing nails (Ring shank preferred). Use of every other anchoring point in the field is acceptable. For exposure more than 5 days and up to 180 days UDL25 product must be anchored with 1" plastic or metal cap smooth or ring shank roofing nails. Miami-Dade approved tin tags and nails or metal caps are also acceptable, and it is recommended for best performance to use with the rough edge facing up. For extended exposure it is always recommended to anchor on every printed position on the facer. Note: UDL25 is not designed for indefinite outdoor exposure. For extended exposure conditions where driving rain or strong winds are expected it is recommended to take additional precautions such as doubling the lap widths. Alternately or in addition to a compatible sealant could be used between the laps or a peel and stick tape could be applied to the overlaps. CAUTION - READ GOOD SAFETY PRACTICES BELOW Good safety practices should be followed on steep slope roofs, such as use of tie-offs, toe boards, ladders and/or safety ropes and personal body harnesses. Follow OSHA guidelines. Slip resistance may vary with surface conditions from debris that accumulates, weather, footwear and roof pitch. Failure to use proper safety gear can result in serious injury. Depending on roof pitch and surface conditions, blocking may be required to support materials on the roof and is good safety practice. Remember to seal the fastener holes that secured the blocking after they have been removed.

DISTRIBUTED BY:

ASPHALT SHINGLES, RESIDENTIAL METAL, SHAKE & COMPOSITE SHINGLES PERFECT FOR USE UNDER: FOR USE NDER:

TITANIUM ® UDL vs. ROOFING FELT

TITANIUM ®

FELT

Lifetime Warranty Inert to mold growth High resistance to wind Does not absorb water & wrinkle Does not dry out & degrade

Does not leach oil Class A fire rating * Meeting class 4 hail rating Supports building green

TECHNICAL COMPARISON

UDL25 15 LB FLET 30 LB FLET

Width

48"

36"

36"

Length per roll

250 ft.

144 ft. 3 rolls 12 rolls

72 ft. 5 rolls

Rolls per 1000 sq. ft. Rolls required per

1 roll

TITANIUM ®

5 rolls

24 rolls

5000 sq. ft. roof

(125 lbs)

(420 lbs) (744 lbs)

• Over 1,000,000 homes are protected under Titanium • Titanium does not break down, dry out and degrade like felt • Synthetic material avoids potential chemical incompatibility between primary roofing and petrolium empregnated felt • Storm protection - stronger waterproof membrane acts as a secondary layer of protection • Reduces liability - safer slip resistant walking surface NOTES

L I M I T E D W A R R A N T Y

SUPERIOR WALKABILITY!

Patented Sure-Foot nodular walking surface

D226 Felt weights and measures are nominal and may vary from manufacturer o manfacturer. * ASTM D226 UL market felts are the only felts with a class A rating. † See actual warranty for compete coverage and restrictions

Titanium® UDL25 is a highly engineered, mechanically attached, coated woven synthetic roofing underlayment designed for sloped roofs. UDL25 represents the future in felt replacement technology, and used in conjunction with Titanium PSU30 self-adhered underlayment, offers the sloped roofing industry a truly revolutionary system of safety, security and simplicity. UDL25’s advanced polymers combine to deliver a unique gray synthetic roofing underlayment that can be used under all types of primary roofing materials to replace #30 felt. Gray technology provides for a cooler working surface during installations and up to a 6 month UV exposure. Unlike smooth surfaced underlayments, UDL25 possesses a revolutionary patented slip resistant Sure-Foot® nodular walking surface technology that allows for easier steep slope walkability, even in wet conditions. Gain an edge in productivity and profits; UDL25’s light weight, 48” width and 250 ft run length allows for fewer laps, cuts and easier roll handling compared to felt. This means you can do more jobs in less time, use less labor, and inventory fewer rolls. UDL25 is 100% synthetic, therefore totally unaffected by water, which means it is 100% inert to mold, lays flat and will not wrinkle. Stay on track, take on more jobs and sleep assured that your UDL25 projects will remain intact and dried-in. Unlike felts, UDL25 does not dry out, leach oils in the heat, nor does it become stiff, difficult to roll or crack in the cold.

• Up to 6 months UV exposure rating • Meets and exceeds ASTM D226 Types I & II • ICC ES Approved • Class A Fire ASTM E108 • CAN/CSA A220.1 • Meets Class 4 Hail Rating • Florida Building Code Approved • Texas Department of Insurance • 11 times lighter and 14 times stronger than #30 felt • Contributes to LEED ® points, 100% Recyclable • All temperature performance -40°F to 240°F • Synthetic construction inert to mold growth • Cool gray surface, doesn’t expand or contract • Dual logo custom printing available

UDL25 is 14 times stronger than #30 felt, gone are the days of blow-offs and call backs! Exceptional tear strength and up

TITANIUM UDL25 ROLL SPECS 250' / 76.2 m 48" / 122 cm

© 2019 Owens Corning. All Rights Reserved.

to 6 months exposure time allows your job to stay on track through all kinds of wind and weather. Less material damage and waste during installation and fewer post-install repairs result in significant savings in time and money. UDL25 will continue to protect your high cost, long life rated, primary roofing long after oil saturated felt products have turned to dust!

LENGTH PER ROLL: WIDTH PER ROLL: WEIGHT PER ROLL: ROLL SIZE: ROLLS PER PALLET: PALLET WEIGHT:

25 lbs / 11.5 kg 10 sq / 93 m 2 56 1,450 lbs / 658 kg

TITANIUM UDL25 TECHNICAL DATA

TITANIUMUDL25 TYPICAL VALUE

ASTM #30 FELT TYPICAL VALUE

TEST & STANDARD †

CLASS A FIRE ASTM E108 PERMEABILITY ASTM E96

Pass

N/A

.06 perms

1.75 perms

WATER TRANSMISSION ASTM D4869 TEAR STRENGTH ASTM D4533 TENSILE STRENGTH ASTM D751 BURST STRENGTH ASTM D751

Pass

Pass

MD 31 lbs (14 kg) | CD 27 lbs (12.5 kg)

MD 4 lbs (1.8 kg) | CD 2 lbs (0.9 kg)

MD 135 lbs (61 kg) | CD 100 lbs (45.5 kg) MD 70 lbs (32 kg) | CD 38 lbs (17 kg)

220 psi (1517 kPa) MD 17% CD 20% 2.4 lbs ( 1.1 kgs) 15 mils (0.38 mm)

62 psi (430 kPa) MD 2% CD 2% 27.5 lbs ( 12.5 kgs) 60 mils (1.5 mm)

ELONGATION ASTM D751

WEIGHT PER SQUARE ASTM D5261 MINIMUM THICKNESS ASTM D1777

TITANIUM ® Synthetic Roo ng Underlayment Charleston, SC • Mission, BC • Montréal, QC Email: answers@owenscorning.com Toll Free: 800.567.9727 eavetopeak.com

Turn your next roofing job into a . . .

† Titanium brand products are manufactured in accordance with national standards which allow for non-critical variances in weights and measurements.Test data is based on an average taken over several production runs and should not be considered or interpreted as maximum or minimum values. Values are typical data and not limiting specifications. All values ± 10%. © 2019 Owens Corning. All Rights Reserved. Pub No. 10021436-A May 2020

Inquire today about Dual Logo printing on Titanium UDL25 Synthetic Underlayment.

INSTALLATION INSTRUCTIONS Titanium ® UDL30 is an air, water and vapor barrier (.06 perms) and therefore should be installed above a properly ventilated space(s). It is recommended to follow all building codes applicable to your geographical region and structure type. DECK PREP: All protrusions from the deck area must be removed and ensure the deck has no voids, damaged or unsupported areas. Deck surface should be free of debris, dry and moisture free. USE: UDL30 must be covered by primary roofing within 180 days of application. UDL30 is designed for use under all primary roofing types including; Metal, Shake and Shingle roofing. APPLICATION: For slopes 4:12 and higher UDL30 is to be laid out horizontally (parallel) to the eave with the printed side up. Horizontal laps should be 4" and vertical laps should be 6"and anchored approximately 1" in from the edge. For low slope applications (less than 4:12) it is recommended to overlap 50% plus 1", for complete definition of low slope and guidelines consult authorities having jurisdiction. UDL30 product is not recommended for slopes less than 2:12. The use of a roofing hammer, hatchet hammer, pneumatic air or gas driven fastener tools is acceptable. The use of a straight edge cutting knife is recommended. FASTENERS: For same day coverage with primary roofing UDL30 can be anchored with corrosive resistant 3/8" head x 1" leg roofing nails (ring shank preferred, smooth leg acceptable). The use of every other anchoring location printed on the product is also acceptable. DO NOT USE STAPLES: The use of staples to penetrate UDL30 will void warranty. ANCHORING: All anchoring nails must be flush, 90 degrees to the roof deck, and tight with the underlayment surface and the structural roof deck. Where seams and joints require sealant or adhesive use a low solvent plastic roofing cement meeting ASTM D-4586 Type 1, or Federal Spec SS-153 Type 1 such as Karnak, Henry, DAP, MB, Geocel or equivalent. Acceptable alternatives are butyl rubber, urethane, and EDPM based caulk or tape sealant. EXTENDED EXPOSURE: If Titanium UDL30 product will be exposed longer than 1 day but less than 5 days then it is recommended to anchor using corrosive resistant 3/8" head x 1" leg roofing nails (Ring shank preferred). Use of every other anchoring point in the field is acceptable. For exposure more than 5 days and up to 180 days UDL30 product must be anchored with 1" plastic or metal cap smooth or ring shank roofing nails. Miami-Dade approved tin tags and nails or metal caps are also acceptable, and it is recommended for best performance to use with the rough edge facing up. For extended exposure it is always recommended to anchor on every printed position on the facer. Note: UDL30 is not designed for indefinite outdoor exposure. For extended exposure conditions where driving rain or strong winds are expected it is recommended to take additional precautions such as doubling the lap widths. Alternately or in addition to a compatible sealant could be used between the laps or a peel and stick tape could be applied to the overlaps. CAUTION - READ GOOD SAFETY PRACTICES BELOW Good safety practices should be followed on steep slope roofs, such as use of tie-offs, toe boards, ladders and/or safety ropes and personal body harnesses. Follow OSHA guidelines. Slip resistance may vary with surface conditions from debris that accumulates, weather, footwear and roof pitch. Failure to use proper safety gear can result in serious injury. Depending on roof pitch and surface conditions, blocking may be required to support materials on the roof and is good safety practice. Remember to seal the fastener holes that secured the blocking after they have been removed.

DISTRIBUTED BY:

NO COATING HERE. THIS RED BOX SHOULD NOT PRINT

ASPHALT SHINGLES, RESIDENTIAL METAL, SLATE, SHAKE & COMPOSITE SHINGLES FOR USE UNDER:

Lifetime Warranty Inert to mold growth High resistance to wind Does not absorb water & wrinkle Does not dry out & degrade TITANIUM ® UDL30 vs. ROOFING FELT

TITANIUM ®

FELT

Does not leach oil Class A fire rating * Meeting class 4 hail rating Supports building green

TECHNICAL COMPARISON

UDL30 15 LB FLET 30 LB FLET

Width

48"

36"

36"

Length per roll

250 ft.

144 ft. 3 rolls 12 rolls

72 ft. 5 rolls

Rolls per 1000 sq. ft. Rolls required per

1 roll

TITANIUM ®

5 rolls

24 rolls

5000 sq. ft. roof

(200 lbs)

(420 lbs) (744 lbs)

• Over 1,000,000 homes are protected under Titanium • Titanium does not break down, dry out and degrade like felt • Synthetic material avoids potential chemical incompatibility between primary roofing and petrolium empregnated felt • Storm protection - stronger waterproof membrane acts as a secondary layer of protection • Reduces liability - safer slip resistant walking surface NOTES

L I M I T E D W A R R A N T Y

SUPERIOR WALKABILITY!

Patented Sure-Foot nodular walking surface

D226 Felt weights and measures are nominal and may vary from manufacturer o manfacturer. * ASTM D226 UL market felts are the only felts with a class A rating. † See actual warranty for compete coverage and restrictions

Titanium ® UDL30 is a highly engineered, mechanically attached, coated woven synthetic roofing underlayment designed for sloped roofs. UDL30 represents the future in felt replacement technology, and used in conjunction with Titanium PSU30 self-adhered underlayment, offers the sloped roofing industry a truly revolutionary system of safety, security and simplicity. UDL30’s advanced polymers combine to deliver a unique gray synthetic roofing underlayment that can be used under all types of primary roofing materials to replace #30 felt. Gray technology provides for a cooler working surface during installations and up to a 6 month UV exposure. Unlike smooth surfaced underlayments, UDL30 possesses a revolutionary patented slip resistant Sure-Foot ® nodular walking surface technology that allows for easier steep slope walkability, even in wet conditions. Gain an edge in productivity and profits; UDL30’s light weight, 48” width and 250 ft run length allows for fewer laps, cuts and easier roll handling compared to felt. This means you can do more jobs in less time, use less labor, and inventory fewer rolls. UDL30 is 100% synthetic, therefore totally unaffected by water, which means it is 100% inert to mold, lays flat and will not wrinkle. Stay on track, take on more jobs and sleep assured that your UDL30 projects will remain intact and dried-in. Unlike felts, UDL30 does not dry out, leach oils in the heat, nor does it become stiff, difficult to roll or crack in the cold.

• Up to 6 months UV exposure rating • Meets and exceeds ASTM D226 Types I & II • ICC ES Approved • Class A Fire ASTM E108 • CAN/CSA A220.1 • Meets Class 4 Hail Rating • 6 times lighter and 20 times stronger than #30 felt • Contributes to LEED ® points, 100% Recyclable • All temperature performance -40°F to 240°F • Synthetic construction inert to mold growth • Cool gray surface, doesn’t expand or contract • Dual logo custom printing available • Florida Building Code Approved • Texas Department of Insurance

UDL30 is 20 times stronger than #30 felt, gone are the days of blow-offs and call backs! Exceptional tear strength and up

TITANIUM UDL30 ROLL SPECS 250' / 76.2 m 48" / 122 cm

to 6 months exposure time allows your job to stay on track through all kinds of wind and weather. Less material damage and waste during installation and fewer post-install repairs result in significant savings in time and money. UDL30 will continue to protect your high cost, long life rated, primary roofing long after oil saturated felt products have turned to dust!

LENGTH PER ROLL: WIDTH PER ROLL: WEIGHT PER ROLL: ROLL SIZE: ROLLS PER PALLET: PALLET WEIGHT:

40 lbs / 18.2 kg 10 sq / 93 m 2 30 1,250 lbs / 567 kg

TITANIUM UDL30 TECHNICAL DATA

TITANIUMUDL30 TYPICAL VALUE

ASTM #30 FELT TYPICAL VALUE

TEST & STANDARD †

CLASS A FIRE ASTM E108 PERMEABILITY ASTM E96

Pass

N/A

.06 perms

1.75 perms

WATER TRANSMISSION ASTM D4869 TEAR STRENGTH ASTM D4533 TENSILE STRENGTH ASTM D751 BURST STRENGTH ASTM D751

Pass

Pass

MD 44 lbs (20 kg) | CD 40 lbs (18 kg) MD 143 lbs (65 kg) | CD 110 lbs (50 kg)

MD 4 lbs (1.8 kg) | CD 2 lbs (0.9 kg) MD 70 lbs (32 kg) | CD 38 lbs (17 kg)

250 psi (1720 kPa) MD 18% CD 18% 4 lbs ( 1.82 kgs) 25 mils (0.63 mm)

62 psi (430 kPa) MD 2% CD 2% 27.5 lbs ( 12.5 kgs) 60 mils (1.5 mm)

ELONGATION ASTM D751

WEIGHT PER SQUARE ASTM D5261 MINIMUM THICKNESS ASTM D1777

TITANIUM ® Synthetic Roo ng Underlayment Charleston, SC • Mission, BC • Montréal, QC Email: answers@owenscorning.com Toll Free: 800.567.9727 eavetopeak.com

Turn your next roofing job into a . . .

† Titanium brand products are manufactured in accordance with national standards which allow for non-critical variances in weights and measurements.Test data is based on an average taken over several production runs and should not be considered or interpreted as maximum or minimum values. Values are typical data and not limiting specifications. All values ± 10%. © 2020 Owens Corning. All Rights Reserved. Pub No. 10021438-A May 2020

Inquire today about Dual Logo printing on Titanium UDL30 Synthetic Underlayment.

Made with FlippingBook Publishing Software